How To Pass Part E Building Regulations

Understanding Part E of the UK Building Regulations: Soundproofing Requirements

The UK Building Regulations encompass many standards to ensure buildings are safe, healthy, and efficient. One critical aspect of these regulations is Part E, which focuses on the acoustic performance of buildings. Approved Document E outlines the requirements for soundproofing in domestic and commercial properties to create environments that protect occupants from excessive noise.

What is Part E?

Part E of the Building Regulations deals specifically with the resistance to the passage of sound. This section addresses sound insulation between and within dwellings and other buildings where people may live, work, or sleep. The goal is to minimise noise disruption and improve the quality of life by ensuring adequate sound insulation is incorporated during the construction and renovation of buildings.

Part E Performance Standards

Dwelling-houses and flats – performance standards for separating walls, separating floors, and stairs that have a separating function Airborne sound insulation DnT,w + Ctr dB (Minimum values) Impact sound insulation L'nT,w dB (Maximum values)
Purpose built dwellings house & flats
Walls 45dB -
Floors & stairs 45dB 62
Dwelling-houses and flats formed by material change of use
Walls 43dB -
Floors & stairs 43dB 64
Rooms for residential purposes – performance standards for separating walls, separating floors, and stairs that have a separating function
Purpose built rooms for residential purposes
Walls 43dB -
Floors & stairs 45dB 62
Rooms for residential purposes formed by material change of use
Walls 43dB -
Floors & stairs 43dB 64

You can download the complete Part E Document here.

Key Sections of Part E

Section E1: Protection Against Sound from Other Parts of the Building and Adjoining Buildings

Section E1 sets out the requirements for limiting the transmission of airborne and impact sound between different parts of a building or between adjoining buildings. This is particularly important in multi-family dwellings such as flats, terraced houses, and commercial buildings where various activities might generate noise.

  • Airborne Sound Insulation: This refers to the ability of a building element to reduce the amount of sound passing through it. Examples include walls and floors that separate one dwelling from another.
  • Impact Sound Insulation: This focuses on minimising noise resulting from impacts on floors, such as footsteps or furniture movement. Effective impact sound insulation often involves using resilient materials and construction techniques that absorb and dampen these noises.

To comply with Section E1, builders and developers must ensure that separating walls and floors meet specific performance standards. Additionally, pre-completion testing is required to verify that the sound insulation measures are effective.

Section E2: Protection Against Sound Within a Dwelling-House

Section E2 addresses sound insulation within individual dwelling units. This includes ensuring that internal walls and floors provide adequate sound resistance to prevent noise from travelling between rooms, particularly in high noise sensitivity, such as bedrooms and bathrooms.

However, there are exceptions to this requirement:

  • Internal walls containing a door
  • Internal walls separating an en-suite toilet from the associated bedroom
  • Existing walls and floors in buildings undergoing material change of use

Practical Implementation and Testing

Workmanship and Materials

Proper workmanship and suitable materials are crucial for achieving the sound insulation standards set out in Part E. Builders must pay attention to detail when constructing separating walls and floors, ensuring that all joints and connections are properly sealed to prevent sound leakage. Common soundproofing materials include dense materials like concrete and brick, as well as specialised acoustic insulation products.

Pre-Completion Sound Testing

part e sound testing

Under Part E, pre-completion sound testing is mandatory to ensure that sound insulation measures meet the required standards. This involves conducting tests to measure airborne and impact sound insulation. The results of these tests must be documented and provided to Building Control to demonstrate compliance.

Building Types Covered by Part E

Part E applies to a wide range of building types, including:

  • Detached houses
  • Semi-detached houses
  • Terraced houses
  • Flats and apartments
  • Student accommodations
  • Hotels

The regulations cover new constructions, conversions, and extensions, ensuring that all types of residential buildings provide suitable sound insulation.

Part E Solutions

Noisestop Systems provides soundproofing solutions for walls, floors and ceilings to meet Part E.

  • Part E soundproofing solutions for separating walls
  • Part E soundproofing solutions for separating floors
  • Part E soundproofing solutions for separating  ceilings

Part E Solutions

Part E soundproofing products

Popular soundproofing categories

Soundproofing posts

Get in touch

If you’d like any help or advice, or would like to chat to us, please call or fill out this form and we’ll be back in touch shortly